羞羞小视频在线观看_羞羞视频免费入口网站_羞羞视频下载APP_男女羞羞视频软件

Bundle Optical Fiber Connector

Products feature

  • Fusion Wiring of Multi-Core Optical Cable in Distribution Frame
  • Various types of optical connectors can be installed
  • Low insertion loss, high echo loss
  • High reliability and stability
It is used in the distribution system of the communication network to realize the beauty and convenience of the distribution system. It is used to connect the bundle optical cable with the loose joint in the distribution system. It is made of 4/6/8/12 cores corresponding to the number of connectors. The fan-out 0.9mm chromatographic product meets the national industry standard and the international general GR-1221 specification. Suitable for indoor application in telecommunication and data network system
ModelInsertion loss (GB)Insertion loss (typical value)Echo Loss (GB)Echo Loss (Typical Value)
PC ≦0.3dB≦0.1dB≧40 dB≧45 dB
UPC ≦0.3dB≦0.1dB≧50?dB≧50 dB
APC ≦0.3dB≦0.2dB≧60 dB≧65 dB
Pilot projectsTest conditions
Warm and Humid AgingThe insertion loss varies less than 0.1dB in 14 days at 85 C and 85% relative humidity.
Temperature CycleTemperature - 40 C to + 75 C, 10% - 80% relative humidity, 42 cycles, 14 days insertion loss change < 0.1dB
Soak in water43℃, PH5.5, 7 days insertion loss change < 0.1dB
VibrationAmplitude 1.52 mm, frequency 10 Hz-55 Hz, insertion loss change of X, Y and Z direction < 0.1 dB in 2 hours each
Load BendingInsertion Loss Change of 0.454kg Load 100 Cycle (Included Set) Less than 0.1dB
Load torsionInsertion Loss Change of 0.454kg Load 10 Cycles (Included Sleeve) Less than 0.1dB
Tension resistance0.23 kg tension (bare fiber), 1.0 kg insertion loss change < 0.1 dB
To attack1.8m high, three directions, 8 times/direction insertion loss change less than 0.1dB